hydro pressure on rect. tank configurations | |||
Post Reply | Forum |
Posted by: Scooter ® 03/27/2006, 14:29:14 Author Profile eMail author Edit |
Can someone please tell me if, while finding the "z" sect. mod. for wall supports to hold fluids in a rect. storage tank, if I must compute a combination of liquid weight as well as pressure.
The wall height is approx. 8'6", width is 8'6", and length is approx. 42'. Liquid is 16#/gal. Thank You. |
Post Reply | Recommend | Alert Administrator | View All | | Next | |
Replies to this message |
Re: hydro pressure on rect. tank configurations | |||
Re: hydro pressure on rect. tank configurations -- Scooter | Post Reply | Top of thread | Forum |
Posted by: zekeman ® 03/28/2006, 15:11:27 Author Profile eMail author Edit |
Tank pressure does not enter the equation, only external forces do, namely gravity ( or weight if you will). |
Post Reply | Recommend | Alert Administrator | Where am I? Original Top of thread | | | |
Re: hydro pressure on rect. tank configurations | |||
Re: Re: hydro pressure on rect. tank configurations -- zekeman | Post Reply | Top of thread | Forum |
Posted by: Scooter ® 03/29/2006, 09:42:50 Author Profile eMail author Edit |
THANKS FOR THE INFO. I WILL HAVE A LATTER POSTING THAT WILL BETTER DISCRIBE MY PROBLEM. HOPE YOU WILL WATCH FOR IT. THANKS AGAIN |
Post Reply | Recommend | Alert Administrator | Where am I? Original Top of thread |
Powered by Engineers Edge