Related Resources: pressure-vessel
Pressure Vessel Temperature Ratings for Group 1.3 Materials per. ASME B16.5 Pipes Flanges and Flanged Fittings
Structural Design and Analysis
Pressure Vessel Design and Engineering
Pressure Vessel Temperature Ratings for Group 1.3 Materials per. ASME B16.5 Pipes Flanges and Flanged Fittings.
1 bar = 14.5038 psi
Designation
|
Forgings
|
Castings
|
Plates
|
C–Si
|
-
|
A 352 Gr. LCB (3) |
A 515 Gr. 65 (1)
|
C–Mn–Si
|
-
|
-
|
A 516 Gr. 65 (1), (2)
|
2 1⁄2 Ni
|
-
|
A 217 Gr. Wc1 (4), (5)
A 352 Gr. LC1 (3) |
A 203 Gr. A (1)
|
3 1⁄2 Ni
|
-
|
-
|
A 203 Gr. D (1)
|
MOST calculators require a Premium Membership
Bars to PSI and PSI to bars pressure conversion calculator
All pressure. given in Bars.
Temp.,°C
|
150
|
300
|
400
|
600
|
900
|
1500
|
2500 |
−29 to 38
|
18.4
|
48.0
|
64.0
|
96.0
|
144.1
|
240.1
|
400.1
|
50
|
18.2
|
47.5
|
63.3
|
94.9
|
142.4
|
237.3
|
395.6
|
100
|
17.4
|
45.3
|
60.5
|
90.7
|
136.0
|
226.7
|
377.8
|
150
|
15.8
|
43.9
|
58.6
|
87.9
|
131.8
|
219.7
|
366.1
|
200
|
13.8
|
42.5
|
56.7
|
85.1
|
127.6
|
212.7
|
354.4
|
250
|
12.1
|
40.8
|
54.4
|
81.6
|
122.3
|
203.9
|
339.8
|
300
|
10.2
|
38.7
|
51.6
|
77.4
|
116.1
|
193.4
|
322.4
|
325
|
9.3
|
37.6
|
50.1
|
75.2
|
112.7
|
187.9
|
313.1
|
350
|
8.4
|
36.4
|
48.5
|
72.8
|
109.2
|
182.0
|
303.3
|
375
|
7.4
|
35.0
|
46.6
|
69.9
|
104.9
|
174.9
|
291.4
|
400
|
6.5
|
32.6
|
43.5
|
65.2
|
97.9
|
163.1
|
271.9
|
425
|
5.5
|
27.3
|
36.4
|
54.6
|
81.9
|
136.5
|
227.5
|
450
|
4.6
|
21.6
|
28.8
|
43.2
|
64.8
|
107.9
|
179.9
|
475
|
3.7
|
15.7
|
20.9
|
31.3
|
47.0
|
78.3
|
130.6
|
500
|
2.8
|
11.1
|
14.8
|
22.1
|
33.2
|
55.4
|
92.3
|
538
|
1.4
|
5.9
|
7.9
|
11.8
|
17.7
|
29.5
|
49.2
|
NOTES:
(1) Upon prolonged exposure to temperatures above 425°C, the carbide phase of steel may be converted to graphite. Permissible, but not recommended for prolonged use above 425°C.
(2) Not to be used over 455°C.
(3) Not to be used over 340°C.
(4) Upon prolonged exposure to temperatures above 465°C, the carbide phase of steel may be converted to graphite. Permissible, but not recommended for prolonged use above 465°C.
(5) Use normalized and tempered material only.