Related Resources: hardware
Metric Prevailing Torque Specification
Metric Engineering Hardware Design Guide
ANSI Engineering Hardware Design Guide Inch Sizes
Prevailing Torque Specification Guide for Metric ISO Hardware Sizes
Related:
METRIC |
PREVAILING |
INSTALLATION |
|||||||
Class 8 |
Class 10 |
||||||||
Nominal |
Thread |
ISO |
Security (Nm) |
Clamp |
Dry |
Lubricated |
Clamp |
Dry |
Lubricated |
10 |
1.50 |
1.4 |
3.0 |
22,181 |
44 |
33 |
30,662 |
61 |
46 |
10 |
1.25 |
1.4 |
3.0 |
23,408 |
47 |
35 |
32,359 |
65 |
49 |
12 |
1.75 |
2.1 |
4.0 |
32,232 |
77 |
58 |
44,556 |
107 |
80 |
12 |
1.25 |
2.1 |
4.0 |
35,218 |
85 |
63 |
48,683 |
117 |
88 |
16 |
2.00 |
4.2 |
6.0 |
59,926 |
192 |
144 |
82,838 |
265 |
199 |
16 |
1.50 |
4.2 |
6.0 |
63,973 |
205 |
154 |
88,433 |
283 |
212 |
20 |
2.50 |
7.0 |
15.0 |
93,634 |
375 |
281 |
129,435 |
518 |
388 |
20 |
1.50 |
7.0 |
15.0 |
103,850 |
415 |
312 |
143,558 |
574 |
431 |
24 |
3.00 |
10.5 |
20.0 |
134,833 |
647 |
485 |
186,387 |
895 |
671 |
24 |
2.00 |
10.5 |
20.0 |
147,039 |
706 |
529 |
203,260 |
976 |
732 |
27 |
3.00 |
12.0 |
22.0 |
175,723 |
949 |
712 |
243,084 |
1,313 |
984 |
27 |
2.00 |
12.0 |
22.0 |
189,621 |
1,024 |
768 |
262,309 |
1,416 |
1,062 |
30 |
3.50 |
14.0 |
26.0 |
214,425 |
1,287 |
965 |
296,411 |
1,778 |
1,334 |
30 |
2.00 |
14.0 |
26.0 |
237,610 |
1,426 |
1,069 |
328,460 |
1,971 |
1,478 |
33 |
3.50 |
15.5 |
29.0 |
265,284 |
1,751 |
1,313 |
366,717 |
2,420 |
1,815 |
33 |
2.00 |
15.5 |
29.0 |
291,006 |
1,921 |
1,440 |
402,273 |
2,655 |
1,991 |
36 |
4.00 |
17.5 |
30.0 |
312,397 |
2,249 |
1,687 |
431,842 |
3,109 |
2,332 |
36 |
3.00 |
17.5 |
30.0 |
330,839 |
2,382 |
1,787 |
457,336 |
3,293 |
2,470 |
39 |
4.00 |
19.5 |
33.0 |
373,226 |
2,911 |
2,183 |
515,930 |
4,024 |
3,018 |
39 |
3.00 |
19.5 |
33.0 |
393,359 |
3,068 |
2,301 |
543,761 |
4,241 |
3,181 |
1) Installation torque and clamp load are calculated using the proof load for the class bolt and nut specified multiplied by 0.75 for a factor of safety and multiplied by 0.85 to account for material removal for the locking mechanism. Proof load used for Class 8 calculation is 600 N/mm2. Proof load used for Class 10 calculation is 830 N/mm2.
2) The value shown is the approximate installation and removal prevailing torque for the Security Locknut. The prevailing torque will vary less than 75% from the value shown from the first to the fifth installation and beyond.
3) Calculated using formula: Nominal diameter x Clamp Load (from note 1) x Friction factor (dimensionless value of 0.20 for dry installation).